The wizard is used for targeted navigation through the subject areas relevant to initial commissioning. Setting the parameters correctly enables subsequent controlled movement of the drive by way of the manual mode window. For exact adaptation of the drive system to an application, further settings need to be made.
If DriveManager 5 is opened with no project, a prompt appears asking if you want to carry out initial commissioning.
If this pop-up does not appear automatically, but you want to carry out commissioning using the wizard, you can also open the commissioning window again by clicking the pictogram or by way of the project tree. If the drive moves in an uncontrolled manner, or does not move at all, after initial commissioning, the parameter inputs must be checked.
Bild: Prompt to activate wizard
Commissioning with wizard
The wizard helps you with the initial configuration of the controller. Work through the individual subject areas in the specified sequence. Then the motor and controller will be set up.
Bild: Commissioning wizard dialog box
Subject area | Action | Instruction |
---|---|---|
Set the switching frequency and the voltage supply of the power stage. | Adaptation of voltage supply to switching frequency | |
Parameter P 0450 MOT_Type is automatically set to PSM if parameter P 0490_ MOT_IsLinMot = LIN(1). |
Selection of motor | |
Selection for a linear motion system with P 0490 = LIN(1) |
Selection of motor system | |
Data set calculation: Fill out "Calculation of control setup for linear synchronous motors" dialog box and start calculation |
Calculation of motor data set | |
|
Motor protection | |
|
Encoder setting | |
|
Automatic tests | |
Open manual mode window
|
Motor test in manual mode without intervention of a higher-level PLC | |
Optimize current controller (test signal generator). When there is a motor data set the current of the test signal generator is set automatically. Optimize speed controller Determine mass inertia [J] (basic settings) Speed filter setting: |
Controller setting
|
|
Setting:
|
Motion profile setting | |
Limits:
|
Define limits | |
Scaling, IOs, field buses:
|
Set marginal conditions. For more information refer to the user manuals for the individual bus systems. |
|
Saving the settings: Create a commissioning file |
Saving: For more information on data handling refer to the Online Help in DriveManager 5 |
Tabelle: Commissioning wizard instructions
Copyright © LTi DRiVES GmbH, Januar 2013, ID-Nr.: 0842.26B.1-00 DE